Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33.262
Filtrar
1.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771899

RESUMO

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Ecocardiografia Doppler , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Tomografia Computadorizada Multidetectores/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Estudos Retrospectivos , Idoso , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Calcinose/mortalidade , Ecocardiografia Doppler/métodos , Idoso de 80 Anos ou mais , Prognóstico , Curva ROC , Hemodinâmica , Pessoa de Meia-Idade , Fatores de Risco
4.
Scand Cardiovasc J ; 58(1): 2353070, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38757904

RESUMO

Objectives: The role of diabetes mellitus as a risk factor for the development of calcific aortic valve disease has not been fully clarified. Aortic valve interstitial cells (VICs) have been suggested to be crucial for calcification of the valve. Induced calcification in cultured VICs is a good in vitro model for aortic valve calcification. The purpose of this study was to investigate whether increased glucose levels increase experimentally induced calcification in cultured human VICs. Design: VICs were isolated from explanted calcified aortic valves after valve replacement. Osteogenic medium induced calcification of cultured VICs at different glucose levels (5, 15, and 25 mM). Calcium deposits were visualized using Alizarin Red staining and measured spectrophotometrically. Results: The higher the glucose concentration, the lower the level of calcification. High glucose (25 mM) reduced calcification by 52% compared with calcification at a physiological (5 mM) glucose concentration (correlation and regression analysis: r = -0.55, p = .025 with increased concentration of glucose). Conclusions: In vitro hyperglycemia-like conditions attenuated calcification in VICs. High glucose levels may trigger a series of events that secondarily stimulate calcification of VICs in vivo.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Glucose , Hiperglicemia , Humanos , Valva Aórtica/patologia , Valva Aórtica/metabolismo , Valva Aórtica/cirurgia , Calcinose/patologia , Calcinose/metabolismo , Células Cultivadas , Glucose/metabolismo , Hiperglicemia/metabolismo , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/cirurgia , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Relação Dose-Resposta a Droga , Osteogênese/efeitos dos fármacos
6.
PLoS One ; 19(5): e0303496, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739622

RESUMO

INTRODUCTION: Rheumatic heart disease (RHD), degenerative aortic stenosis (AS), and congenital valve diseases are prevalent in sub-Saharan Africa. Many knowledge gaps remain in understanding disease mechanisms, stratifying phenotypes, and prognostication. Therefore, we aimed to characterise patients through clinical profiling, imaging, histology, and molecular biomarkers to improve our understanding of the pathophysiology, diagnosis, and prognosis of RHD and AS. METHODS: In this cross-sectional, case-controlled study, we plan to recruit RHD and AS patients and compare them to matched controls. Living participants will undergo clinical assessment, echocardiography, CMR and blood sampling for circulatory biomarker analyses. Tissue samples will be obtained from patients undergoing valve replacement, while healthy tissues will be obtained from cadavers. Immunohistology, proteomics, metabolomics, and transcriptome analyses will be used to analyse circulatory- and tissue-specific biomarkers. Univariate and multivariate statistical analyses will be used for hypothesis testing and identification of important biomarkers. In summary, this study aims to delineate the pathophysiology of RHD and degenerative AS using multiparametric CMR imaging. In addition to discover novel biomarkers and explore the pathomechanisms associated with RHD and AS through high-throughput profiling of the tissue and blood proteome and metabolome and provide a proof of concept of the suitability of using cadaveric tissues as controls for cardiovascular disease studies.


Assuntos
Estenose da Valva Aórtica , Biomarcadores , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/metabolismo , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/metabolismo , Estudos de Casos e Controles , Estudos Transversais , Masculino , Feminino , Metabolômica/métodos , Ecocardiografia/métodos , Proteômica/métodos , Imageamento por Ressonância Magnética/métodos , Multiômica
7.
Sci Rep ; 14(1): 10902, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740898

RESUMO

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Aprendizado Profundo , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/cirurgia , Calcinose/mortalidade , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Análise de Sobrevida , Fatores de Risco , Modelos de Riscos Proporcionais , Medição de Risco/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade
8.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691562

RESUMO

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Septo Interventricular , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Potenciais de Ação
9.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38730543

RESUMO

OBJECTIVES: The aim of this study was to describe trends and outcomes for patients undergoing surgical aortic valve replacement (SAVR) in the Netherlands. METHODS: The Netherlands Heart Registration database was used to report the number and outcomes of isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients. RESULTS: A total of 17 142 procedures were included, of which 77.9% were performed using a biological prosthesis and 21.0% with a mechanical prosthesis. Median logistic EuroSCORE I decreased from 4.6 [interquartile range (IQR) 2.4-7.7] to 4.0 (IQR 2.6-6.0). The 120-day mortality decreased from 3.3% in 2007 to 0.7% in 2018. The median duration of follow-up was 76 months (IQR 53-111). Ten-year survival, when adjusted for age, EuroSCORE I and body surface area, was 72.4%, and adjusted 10-year freedom from reinvervention was 98.1%. Additional analysis for patients under the age of 60 showed no difference between patients treated with a biological or mechanical prosthesis in adjusted 10-year survival, 89.7% vs 91.9±%, respectively (P = 0.25), but a significant difference in adjusted 10-year freedom from reintervention, 90.0±% vs 95.9%, respectively (P < 0.01). CONCLUSIONS: Between 2007 and 2018, age and risk profile of patients undergoing SAVR decreased, especially for patients treated with a biological prosthesis. The 120-day mortality decreased over time. Patients undergoing SAVR nowadays have a risk of 120-day mortality of <1% and 10-year freedom from valve-related reintervention of >95%.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Países Baixos/epidemiologia , Feminino , Idoso , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/tendências , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Próteses Valvulares Cardíacas/tendências , Idoso de 80 Anos ou mais , Sistema de Registros , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Fatores de Risco
10.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710782

RESUMO

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Aorta/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas , Estudos Retrospectivos
13.
Clin Interv Aging ; 19: 695-703, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38711477

RESUMO

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Complicações Pós-Operatórias , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Pessoa de Meia-Idade , Fatores de Risco , Doenças das Valvas Cardíacas/cirurgia
14.
Laeknabladid ; 110(5): 247-253, 2024 May.
Artigo em Islandês | MEDLINE | ID: mdl-38713559

RESUMO

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Humanos , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Masculino , Idoso , Fatores de Risco , Estudos Retrospectivos , Islândia/epidemiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/etiologia , Incidência , Fatores de Tempo , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade
15.
PLoS One ; 19(5): e0302378, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38771808

RESUMO

BACKGROUND: Guidelines recommend shared decision making when choosing treatment for severe aortic stenosis but implementation has lagged. We assessed the feasibility and impact of a novel decision aid for severe aortic stenosis at point-of-care. METHODS: This prospective multi-site pilot cohort study included adults with severe aortic stenosis and their clinicians. Patients were referred by their heart team when scheduled to discuss treatment options. Outcomes included shared decision-making processes, communication quality, decision-making confidence, decisional conflict, knowledge, stage of decision making, decision quality, and perceptions of the tool. Patients were assessed at baseline (T0), after using the intervention (T1), and after the clinical encounter (T2); clinicians were assessed at T2. Before the encounter, patients reviewed the intervention, Aortic Valve Improved Treatment Approaches (AVITA), an interactive, online decision aid. AVITA presents options, frames decisions, clarifies patient goals and values, and generates a summary to use with clinicians during the encounter. RESULTS: 30 patients (9 women [30.0%]; mean [SD] age 70.4 years [11.0]) and 14 clinicians (4 women [28.6%], 7 cardiothoracic surgeons [50%]) comprised 28 clinical encounters Most patients [85.7%] and clinicians [84.6%] endorsed AVITA. Patients reported AVITA easy to use [89.3%] and helped them choose treatment [95.5%]. Clinicians reported the AVITA summary helped them understand their patients' values [80.8%] and make values-aligned recommendations [61.5%]. Patient knowledge significantly improved at T1 and T2 (p = 0.004). Decisional conflict, decision-making stage, and decision quality improved at T2 (p = 0.0001, 0.0005, and 0.083, respectively). Most patients [60%] changed treatment preference between T0 and T2. Initial treatment preferences were associated with low knowledge, high decisional conflict, and poor decision quality; final preferences were associated with high knowledge, low conflict, and high quality. CONCLUSIONS: AVITA was endorsed by patients and clinicians, easy to use, improved shared decision-making quality and helped patients and clinicians arrive at a treatment that reflected patients' values. TRIAL REGISTRATION: Trial ID: NCT04755426, Clinicaltrials.gov/ct2/show/NCT04755426.


Assuntos
Estenose da Valva Aórtica , Tomada de Decisão Compartilhada , Técnicas de Apoio para a Decisão , Estudos de Viabilidade , Preferência do Paciente , Humanos , Estenose da Valva Aórtica/terapia , Estenose da Valva Aórtica/cirurgia , Feminino , Masculino , Projetos Piloto , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso de 80 Anos ou mais , Participação do Paciente , Médicos/psicologia , Relações Médico-Paciente , Tomada de Decisões
16.
Circ Cardiovasc Imaging ; 17(5): e015996, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771906

RESUMO

BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.


Assuntos
Neuropatias Amiloides Familiares , Estenose da Valva Aórtica , Angiografia por Tomografia Computadorizada , Fibrose , Miocárdio , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Miocárdio/patologia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/mortalidade , Valor Preditivo dos Testes , Prognóstico , Angiografia Coronária/métodos , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Pessoa de Meia-Idade
17.
Sci Rep ; 14(1): 11762, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783030

RESUMO

There is limited data on the effect of socioeconomic status (SES) on transcatheter (TAVR) and surgical aortic valve replacement (SAVR) outcomes for aortic stenosis (AS). This study conducted a population-based analysis to assess the influence of SES on valve replacement outcomes. Patients with AS undergoing TAVR or SAVR were identified in National Inpatient Sample from Q4 2015-2020. Multivariable logistic regressions were used to compare in-hospital outcomes between patients living in neighborhoods of income at the lowest and highest quartiles. Of 613,785 AS patients, 9.77% underwent TAVR and 10.13% had SAVR. These rates decline with lower neighborhood income levels, with TAVR/SAVR ratio also declining in lower-income areas. Excluding concomitant procedures, 58,064 patients received isolated TAVR (12,355 low-income and 15,212 high-income) and 43,694 underwent isolated SAVR (10,029 low-income and 10,811 high-income). Low-income patients, in both TAVR and SAVR, were younger but had more comorbid burden. For isolated TAVR, outcomes were similar across income groups. However, for isolated SAVR, low-income patients experienced higher in-hospital mortality (aOR = 1.44, p < 0.01), pulmonary (aOR = 1.13, p = 0.01), and renal complications (aOR = 1.14, p < 0.01). They also had more transfers, longer waits for operations, and extended hospital stays. Lower-income communities had reduced access to TAVR and SAVR, with TAVR accessibility being particularly limited. When given access to TAVR, patients from lower-income neighborhoods had mostly comparable outcomes. However, patients from low-income communities faced worse outcomes in SAVR, possibly due to delays in treatment. Ensuring equitable specialized healthcare resources including expanding TAVR access in economically disadvantaged communities is crucial.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Disparidades em Assistência à Saúde , Pacientes Internados/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca , Estados Unidos/epidemiologia , Mortalidade Hospitalar , Pessoa de Meia-Idade , Fatores Socioeconômicos , Classe Social , Valva Aórtica/cirurgia , Resultado do Tratamento , Disparidades Socioeconômicas em Saúde
18.
A A Pract ; 18(6): e01790, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38785382

RESUMO

This case report describes the rare occurrence of a ventricular septal defect (VSD) after transcatheter aortic valve implantation (TAVI) in an 88-year-old male patient with aortic stenosis and other comorbidities. Initially asymptomatic, the patient was discharged but readmitted 2 weeks later with decompensated heart failure. Transesophageal echocardiography (TEE) revealed an increase in the size of the VSD and right ventricular dilation. Surgical intervention was chosen over percutaneous closure due to the patient's condition. A bovine pericardial patch was successfully used for repair. This case highlights the importance of vigilant post-TAVI monitoring and individualized treatment for TAVI-related complications.


Assuntos
Estenose da Valva Aórtica , Comunicação Interventricular , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Comunicação Interventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Bovinos , Animais , Resultado do Tratamento
19.
Circ Cardiovasc Imaging ; 17(5): e016276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716653

RESUMO

BACKGROUND: Quantification of left atrial (LA) conduit function and its contribution to left ventricular (LV) filling is challenging because it requires simultaneous measurements of both LA and LV volumes. The functional relationship between LA conduit function and the severity of diastolic dysfunction remains controversial. We studied the role of LA conduit function in maintaining LV filling in advanced diastolic dysfunction. METHODS: We performed volumetric and flow analyses of LA function across the spectrum of LV diastolic dysfunction, derived from a set of consecutive patients undergoing multiphasic cardiac computed tomography scanning (n=489). From LA and LV time-volume curves, we calculated 3 volumetric components: (1) early passive emptying volume; (2) late active (booster) volume; and (3) conduit volume. Results were prospectively validated on a group of patients with severe aortic stenosis (n=110). RESULTS: The early passive filling progressively decreased with worsening diastolic function (P<0.001). The atrial booster contribution to stroke volume modestly increases with impaired relaxation (P=0.021) and declines with more advanced diastolic function (P<0.001), thus failing to compensate for the reduction in early filling. The conduit volume increased progressively (P<0.001), accounting for 75% of stroke volume (interquartile range, 63-81%) with a restrictive filling pattern, compensating for the reduction in both early and booster functions. Similar results were obtained in patients with severe aortic stenosis. The pulmonary artery systolic pressure increased in a near-linear fashion when the conduit contribution to stroke volume increased above 60%. Maximal conduit flow rate strongly correlated with mitral E-wave velocity (r=0.71; P<0.0001), indicating that the increase in mitral E wave in diastolic dysfunction represents the increased conduit flow. CONCLUSIONS: An increase in conduit volume contribution to stroke volume represents a compensatory mechanism to maintain LV filling in advanced diastolic dysfunction. The increase in conduit volume despite increasing LV diastolic pressures is accomplished by an increase in pulmonary venous pressure.


Assuntos
Estenose da Valva Aórtica , Função do Átrio Esquerdo , Diástole , Volume Sistólico , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Função do Átrio Esquerdo/fisiologia , Idoso , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Volume Sistólico/fisiologia , Índice de Gravidade de Doença , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valor Preditivo dos Testes
20.
Curr Probl Cardiol ; 49(7): 102629, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38723797

RESUMO

Transcatheter aortic valve implantation (TAVI) is a promising treatment strategy for high-risk surgical patients, and trials investigating its effectiveness in intermediate- and lower-risk patients are underway. Data are inconsistent regarding the superiority of using local anesthesia with conscious sedation alone versus general anesthesia (GA) as the anesthesia management of choice for elderly frail patients. Historically, TAVI procedure is performed under GA with transesophageal echocardiography. This approach gives operators stable hemodynamic control of the patient and helps decrease the risk of many of the operation's documented complications, including paravalvular leak and valve malpositioning. However, some studies have criticized the dependence of GA on mechanical ventilation and an increased need for catecholamine and/or vasopressor agents. Alternatively, to further capitalize on the minimally invasive nature of TAVI, some authors have advocated for the use of local anesthesia (LA) and/or conscious sedation approach, which would decrease procedure time, length of hospital stay, and minimize the need for postoperative inotropes. Ultimately and at present, the choice of anesthesia is based on the personal experience and preference of the Heart Team involved in the TAVI procedure, which will dictate the best possible management plan for each patient. Many patients currently undergoing TAVI are elderly and have multiple comorbidities, making their care complex. Anesthetic care is shifting from GA to sedation and regional block, but life-threatening complications are still relatively common and safety during planning and conduct of these procedures by the heart team, with the anesthesiologist at the center, is paramount.


Assuntos
Anestesia Geral , Anestesia Local , Estenose da Valva Aórtica , Ensaios Clínicos Controlados Aleatórios como Assunto , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Anestesia Geral/métodos , Anestesia Local/métodos , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...